CMD=CMD_0
Master Transmit Data Register
DATA | Transmit Data |
CMD | Command Data 0 (CMD_0): Transmit DATA[7:0] 1 (CMD_1): Receive (DATA[7:0] + 1) bytes 2 (CMD_2): Generate STOP condition 3 (CMD_3): Receive and discard (DATA[7:0] + 1) bytes 4 (CMD_4): Generate (repeated) START and transmit address in DATA[7:0] 5 (CMD_5): Generate (repeated) START and transmit address in DATA[7:0]. This transfer expects a NACK to be returned. 6 (CMD_6): Generate (repeated) START and transmit address in DATA[7:0] using high speed mode 7 (CMD_7): Generate (repeated) START and transmit address in DATA[7:0] using high speed mode. This transfer expects a NACK to be returned. |